DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
TEQUESTA WELLFIELD #5
18_TQ5
952738
959765
Start Test Date:
20-MAY-1980 0000
Aquifer:
SURFICIAL AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
31711
Discharge Rate (gal/min):
218
Horizontal K (ft/day):
Hours Pumped:
36
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
38
Storativity:
.18
Tested Interval Max. (ft BLS):
60
Leakance (1/day):
No. Monitored Wells:
3
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
GEE & JENSEN. From SFWMD files, complete reference unknown
Comments:
Reference contains early & late time estimates, but only late-time estimates included here
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
D1-5_TQ5
952738
956065
BOULTON
23.8
18618
.0037
S1-5_TQ5
952738
959765
BOULTON
51.5
30363
.0098
S2-5_TQ5
952738
959765
BOULTON
99.8
24740
S3-5_TQ5
952738
959765
BOULTON
194.7
39761
Page generated at: 04-OCT-2025 11:43 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?