DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
TEQUESTA WELLFIELD #518_TQ5952738959765

Start Test Date:20-MAY-1980 0000Aquifer:SURFICIAL AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):31711
Discharge Rate (gal/min):218Horizontal K (ft/day):
Hours Pumped:36Vertical K (ft/day):
Tested Interval Min. (ft BLS):38Storativity:.18
Tested Interval Max. (ft BLS):60Leakance (1/day):
No. Monitored Wells:3Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT GEE & JENSEN. From SFWMD files, complete reference unknown
Comments:Reference contains early & late time estimates, but only late-time estimates included here

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
D1-5_TQ5
952738
956065
BOULTON
23.8
18618
.0037
S1-5_TQ5
952738
959765
BOULTON
51.5
30363
.0098
S2-5_TQ5
952738
959765
BOULTON
99.8
24740
S3-5_TQ5
952738
959765
BOULTON
194.7
39761

Page generated at: 04-OCT-2025 11:43 EDT