DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
LEE COUNTY THREE OAKS WASTE WATER TREATMENT PLANT
3OAK-IW1
396730
777524
Start Test Date:
24-FEB-2005 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.53
Discharge Rate (gal/min):
1.6
Horizontal K (ft/day):
.01
Hours Pumped:
4
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1440
Storativity:
Tested Interval Max. (ft BLS):
1480
Leakance (1/day):
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MWH, 2006, THREE OAKS WWTP DRILLING AND TESTING REPORT
117
Comments:
TRANSMISSIVITY CALCULATED FROM DRAWDOWN DATA AND IS AVERAGE OF NEUMANN-WITHERSPOON=.4596, HANTUSH=.5684, HANTUSH-JACOB=.5224, THEIS=.5897, THEIS RECOVERY=.3339, COOPER-JACOB=3.094
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
LEE COUNTY THREE OAKS WASTE WATER TREATMENT PLANT
3OAK-IW1
396730
777524
Start Test Date:
25-FEB-2005 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
67
Discharge Rate (gal/min):
40
Horizontal K (ft/day):
1.68
Hours Pumped:
4
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1150
Storativity:
Tested Interval Max. (ft BLS):
1190
Leakance (1/day):
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MWH, 2006, THREE OAKS WWTP DRILLING AND TESTING REPORT
117
Comments:
TRANSMISSIVITY CALCULATED FROM DRAWDOWN DATA AND IS AVERAGE OF NEUMANN-WITHERSPOON=53.26, PAPADOPULOUS-COOPER=122.4, HANTUSH=53.28, HANTUSH-JACOB=39.1
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
LEE COUNTY THREE OAKS WASTE WATER TREATMENT PLANT
3OAK-IW1
396730
777524
Start Test Date:
27-FEB-2005 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
5.73
Discharge Rate (gal/min):
28
Horizontal K (ft/day):
.14
Hours Pumped:
4
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1630
Storativity:
Tested Interval Max. (ft BLS):
1670
Leakance (1/day):
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MWH, 2006, THREE OAKS WWTP DRILLING AND TESTING REPORT
117
Comments:
TRANSMISSIVITY CALCULATED FROM DRAWDOWN DATA AND IS AVERAGE OF NEUMANN-WITHERSPOON=7.414, COOPER-JACOB=3.094, HANTUSH=7.548, HANTUSH-JACOB=7.137, THEIS RECOVERY=3.434
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
LEE COUNTY THREE OAKS WASTE WATER TREATMENT PLANT
3OAK-IW1
396730
777524
Start Test Date:
03-APR-2005 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
135
Discharge Rate (gal/min):
91
Horizontal K (ft/day):
4.82
Hours Pumped:
4
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2271
Storativity:
Tested Interval Max. (ft BLS):
2299
Leakance (1/day):
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MWH, 2006, THREE OAKS WWTP DRILLING AND TESTING REPORT
117
Comments:
TRANSMISSIVITY CALCULATED FROM DRAWDOWN DATA AND IS AVERAGE OF NEUMANN-WITHERSPOON=151.9, HANTUSH=135.6, HANTUSH-JACOB=119.1, THEIS RECOVERY=130.7
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
LEE COUNTY THREE OAKS WASTE WATER TREATMENT PLANT
3OAK-IW1
396730
777524
Start Test Date:
04-APR-2005 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.84
Discharge Rate (gal/min):
1.7
Horizontal K (ft/day):
.03
Hours Pumped:
4
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2072
Storativity:
Tested Interval Max. (ft BLS):
2100
Leakance (1/day):
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MWH, 2006, THREE OAKS WWTP DRILLING AND TESTING REPORT
117
Comments:
TRANSMISSIVITY CALCULATED FROM DRAWDOWN DATA AND IS AVERAGE OF NEUMANN-WITHERSPOON=0.7333, COOPER-JACOB=0.9851, HANTUSH=0.6702, HANTUSH-JACOB=0.9825, THEIS RECOVERY=0.5894
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
LEE COUNTY THREE OAKS WASTE WATER TREATMENT PLANT
3OAK-IW1
396730
777524
Start Test Date:
05-APR-2005 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.6
Discharge Rate (gal/min):
2
Horizontal K (ft/day):
.02
Hours Pumped:
4
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1920
Storativity:
Tested Interval Max. (ft BLS):
1948
Leakance (1/day):
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MWH, 2006, THREE OAKS WWTP DRILLING AND TESTING REPORT
117
Comments:
TRANSMISSIVITY CALCULATED FROM DRAWDOWN DATA AND IS AVERAGE OF NEUMANN-WITHERSPOON=.5213, COOPER-JACOB=.7237, HANTUSH=.4693, HANTUSH-JACOB=.6529, THEIS RECOVERY=.476
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
LEE COUNTY THREE OAKS WASTE WATER TREATMENT PLANT
3OAK-IW1
396730
777524
Start Test Date:
06-APR-2005 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
5.64
Discharge Rate (gal/min):
5.5
Horizontal K (ft/day):
.31
Hours Pumped:
4
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1819
Storativity:
Tested Interval Max. (ft BLS):
1837
Leakance (1/day):
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
MWH, 2006, THREE OAKS WWTP DRILLING AND TESTING REPORT
117
Comments:
TRANSMISSIVITY CALCULATED FROM DRAWDOWN DATA AND IS AVERAGE OF COOPER-JACOB=3.593, HANTUSH-JACOB=7.037, THEIS RECOVERY=3.057
Page generated at: 04-OCT-2025 12:09 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|