DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
SJRWMD TPSJ93-1: APT SITE OR2831-122-45384831520834

Start Test Date:17-FEB-1961 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):60829
Discharge Rate (gal/min):1100Horizontal K (ft/day):232
Hours Pumped:11Vertical K (ft/day):
Tested Interval Min. (ft BLS):77Storativity:.00071
Tested Interval Max. (ft BLS):364Leakance (1/day):.018
No. Monitored Wells:4Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD SFWMD TECHPUB 84-1149
Comments:WELL D. SITE OR2 FROM SJRWMD TP SJ93-1 COOPER 1963 IS ANALYSIS METHOD

Page generated at: 28-SEP-2024 19:32 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?