DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
Orlando Utilities Commission Southeast Test Well
AIR19W2
542435
1479493
Start Test Date:
10-OCT-1995 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
APT
Transmissivity (ft2/day):
93000
Discharge Rate (gal/min):
2780
Horizontal K (ft/day):
Hours Pumped:
5
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
200
Storativity:
Tested Interval Max. (ft BLS):
1100
Leakance (1/day):
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
91
Source
Reference
Citation Id
CONSULTANT
CH2MHILL, 1996. CONSTRUCTION AND TESTING OF THE ORANGE AND SOUTHEAST TEST WELLS.
Comments:
T CALCULATED USING COOPER-JACOB ANALYSIS OF DRAWDOWN FROM MONITOR WELL 275 FT AWAY. WELL WAS OPEN TO BOTH UPPER FLORIDAN AND MIDDLE-SEMI-CONFIINING UNIT, SO K BASED ON THIS THICKNESS WOULD BE MIS-LEADING. MOST OF THE PRODUCTION WAS ABOVE 500 FT BLS.
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
Orlando Utilities Commission Southeast Test Well
AIR19W2
542435
1479493
Start Test Date:
01-JAN-1996 0000
Aquifer:
LOWER FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
500000
Discharge Rate (gal/min):
Horizontal K (ft/day):
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1098
Storativity:
Tested Interval Max. (ft BLS):
1400
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
Data compiled in USGS WRIR 02-4036, data originally from, CH2M HILL
Comments:
PUMP DATE = REFERENCE REPORT DATE; TRANSMISSIVITY >500k
Page generated at: 04-OCT-2025 11:42 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?