DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
NORTH REGIONAL WASTEWATER TREATMENT PLANTBCN-I6932273702403

Start Test Date:01-JAN-2000 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):4.2
Discharge Rate (gal/min):25Horizontal K (ft/day):.28
Hours Pumped:4.82Vertical K (ft/day):
Tested Interval Min. (ft BLS):1776Storativity:
Tested Interval Max. (ft BLS):1790Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT HAZEN AND SAWYER, JULY, 2000; WELL COMPLETION REPORT, INJECTION WELLS 5 AND 6 CONSTRUCTION COMPLETION REPORT NORTH REGIONAL WASTEWATER TREATMENT PLANT
Comments:TRANSMISSIVITY AND HORIZONTAL K ARE BOTH FROM RECOVERY.



SitePumped WellX-Coord(ft)Y-Coord (ft)
NORTH REGIONAL WASTEWATER TREATMENT PLANTBCN-I6932273702403

Start Test Date:01-JAN-2000 0001Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):1.22
Discharge Rate (gal/min):8Horizontal K (ft/day):.14
Hours Pumped:2.42Vertical K (ft/day):
Tested Interval Min. (ft BLS):1791Storativity:
Tested Interval Max. (ft BLS):1805Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT HAZEN AND SAWYER, JULY, 2000; WELL COMPLETION REPORT, INJECTION WELLS 5 AND 6 CONSTRUCTION COMPLETION REPORT NORTH REGIONAL WASTEWATER TREATMENT PLANT
Comments:TRANSMISSIVITY AND HORIZONTAL K ARE BOTH FROM RECOVERY.



SitePumped WellX-Coord(ft)Y-Coord (ft)
NORTH REGIONAL WASTEWATER TREATMENT PLANTBCN-I6932273702403

Start Test Date:01-JAN-2000 0002Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):13.1
Discharge Rate (gal/min):48Horizontal K (ft/day):.91
Hours Pumped:4.8Vertical K (ft/day):
Tested Interval Min. (ft BLS):1816Storativity:
Tested Interval Max. (ft BLS):1830Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT HAZEN AND SAWYER, JULY, 2000; WELL COMPLETION REPORT, INJECTION WELLS 5 AND 6 CONSTRUCTION COMPLETION REPORT NORTH REGIONAL WASTEWATER TREATMENT PLANT
Comments:TRANSMISSIVITY AND HORIZONTAL K ARE BOTH FROM RECOVERY.



SitePumped WellX-Coord(ft)Y-Coord (ft)
NORTH REGIONAL WASTEWATER TREATMENT PLANTBCN-I6932273702403

Start Test Date:01-JAN-2000 0003Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):1.49
Discharge Rate (gal/min):9Horizontal K (ft/day):.088
Hours Pumped:5.67Vertical K (ft/day):
Tested Interval Min. (ft BLS):1882Storativity:
Tested Interval Max. (ft BLS):1900Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT HAZEN AND SAWYER, JULY, 2000; WELL COMPLETION REPORT, INJECTION WELLS 5 AND 6 CONSTUCTION AND COMPLETION REPORT NORTH REGIONAL WASTEWATER TREATMENT PLANT
Comments:TRANSMISSIVITY AND HORIZONTAL K ARE BOTH FROM RECOVERY.



SitePumped WellX-Coord(ft)Y-Coord (ft)
NORTH REGIONAL WASTEWATER TREATMENT PLANTBCN-I6932273702403

Start Test Date:01-JAN-2000 0004Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):9.21
Discharge Rate (gal/min):41Horizontal K (ft/day):.23
Hours Pumped:7.58Vertical K (ft/day):
Tested Interval Min. (ft BLS):1920Storativity:
Tested Interval Max. (ft BLS):1960Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT HAZEN AND SAWYER, JULY, 2000; WELL COMPLETION REPORT, INJECTION WELLS 5 AND 6 CONSTRUCTION AND COMPLETION REPORT NORTH REGIONAL WASTEWATER TREATMENT PLANT
Comments:TRANSMISSIVITY AND HORIZONTAL K ARE BOTH FROM RECOVERY.

Page generated at: 04-OCT-2025 11:47 EDT