DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
MOBIL STATION #02-FQH, 1501 S CYPRESS RD, POMPANO BEACH, 33062, data compiled by: Broward County Environmental Protection DepartmentBEPD-130943635683620

Start Test Date:06-MAR-1992 0000Aquifer:SURFICIAL AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):10171
Discharge Rate (gal/min):Horizontal K (ft/day):31.79
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2Storativity:
Tested Interval Max. (ft BLS):10Leakance (1/day):
No. Monitored Wells:2Specific Capacity (gpm/ft):
SourceReferenceCitation Id
FLORIDA DEPT OF ENV PROTECTION FDEP OCULUS files compiled by Broward County Environmental Protection Department, FDEP Facility ID #068501801, CONTAMINATION ASSESSMENT REPORT
Comments:Average K and T of 2 Slug Tests., the report date was used as the aquifer test date.

Page generated at: 04-OCT-2025 08:38 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?