DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
TWIN MINI SHOP, 1201 S FEDERAL HWY, DANIA, 33004, data compiled by: Broward County Environmental Protection DepartmentBEPD-173937546619964

Start Test Date:12-JUL-1993 0000Aquifer:SURFICIAL AQUIFER SYSTEM
Test Type:SLUGTransmissivity (ft2/day):7847
Discharge Rate (gal/min):Horizontal K (ft/day):56.02
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):6Storativity:
Tested Interval Max. (ft BLS):16Leakance (1/day):
No. Monitored Wells:2Specific Capacity (gpm/ft):
SourceReferenceCitation Id
FLORIDA DEPT OF ENV PROTECTION FDEP OCULUS files compiled by Broward County Environmental Protection Department, FDEP Facility ID #068502819, CONTAMINATION ASSESSMENT REPORT
Comments:Average K used to calculate T., the report date was used as the aquifer test date.