DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
MOBIL SERVICE STATION, #0, 831 W SUNRISE BLVD, FORT LAUDERDALE, 33311, data compiled by: Broward County Environmental Protection DepartmentBEPD-261933856656336

Start Test Date:12-NOV-1991 0000Aquifer:SURFICIAL AQUIFER SYSTEM
Test Type:SLUGTransmissivity (ft2/day):3588
Discharge Rate (gal/min):12.27Horizontal K (ft/day):32.67
Hours Pumped:1.4Vertical K (ft/day):
Tested Interval Min. (ft BLS):5Storativity:
Tested Interval Max. (ft BLS):20Leakance (1/day):
No. Monitored Wells:1Specific Capacity (gpm/ft):
SourceReferenceCitation Id
FLORIDA DEPT OF ENV PROTECTION FDEP OCULUS files compiled by Broward County Environmental Protection Department
Comments:T used to calculate K., the report date was used as the aquifer test date.

Page generated at: 04-OCT-2025 08:37 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?