DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
BF-1,2 - FLORIDAN AQUIFER WELLS ON C-13BF-1925619669566

Start Test Date:17-FEB-1993 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):110Horizontal K (ft/day):
Hours Pumped:2Vertical K (ft/day):
Tested Interval Min. (ft BLS):2120Storativity:
Tested Interval Max. (ft BLS):2142Leakance (1/day):
No. Monitored Wells:0Specific Capacity (gpm/ft):550
SourceReferenceCitation Id
SOUTH FLORIDA WMD LUKASIEWICZ, LUKASIEWICZ DRAFT WS-15 TECH PUB213
Comments:FRICTION LOSS CORRECTED.

View Water Quality Results for the Above Test



Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
BF-1
925619
669566
THEIS RECOVERY
0
14
4519



SitePumped WellX-Coord(ft)Y-Coord (ft)
BF-1,2 - FLORIDAN AQUIFER WELLS ON C-13BF-1925619669566

Start Test Date:19-FEB-1993 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):4.5Horizontal K (ft/day):
Hours Pumped:17.4Vertical K (ft/day):
Tested Interval Min. (ft BLS):2078Storativity:
Tested Interval Max. (ft BLS):2088Leakance (1/day):
No. Monitored Wells:1Specific Capacity (gpm/ft):.07
SourceReferenceCitation Id
SOUTH FLORIDA WMD LUKASIEWICZ, DRAFT WS-15 TECH PUB213
Comments:2 OF 6 PACKER TESTS CONDUCTED IN BF-1

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
BF-1
925619
669566
THEIS RECOVERY
0
64
4



SitePumped WellX-Coord(ft)Y-Coord (ft)
BF-1,2 - FLORIDAN AQUIFER WELLS ON C-13BF-1925619669566

Start Test Date:23-FEB-1993 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):74Horizontal K (ft/day):
Hours Pumped:2.4Vertical K (ft/day):
Tested Interval Min. (ft BLS):1726Storativity:
Tested Interval Max. (ft BLS):1772Leakance (1/day):
No. Monitored Wells:1Specific Capacity (gpm/ft):5.52
SourceReferenceCitation Id
SOUTH FLORIDA WMD LUKASIEWICZ, WS-15 DRAFT TECH PUB213
Comments:3 OF 6 PACKER TESTS

View Water Quality Results for the Above Test



Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
BF-1
925619
669566
THEIS RECOVERY
0
22
882



SitePumped WellX-Coord(ft)Y-Coord (ft)
BF-1,2 - FLORIDAN AQUIFER WELLS ON C-13BF-1925619669566

Start Test Date:24-FEB-1993 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):63Horizontal K (ft/day):
Hours Pumped:3.3Vertical K (ft/day):
Tested Interval Min. (ft BLS):1644Storativity:
Tested Interval Max. (ft BLS):1690Leakance (1/day):
No. Monitored Wells:1Specific Capacity (gpm/ft):2.31
SourceReferenceCitation Id
SOUTH FLORIDA WMD LUKASIEWICZ, WS-15 DRAFT213
Comments:4 OF 6 PACKER TESTS

View Water Quality Results for the Above Test



Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
BF-1
925619
669566
THEIS RECOVERY
0
33
634



SitePumped WellX-Coord(ft)Y-Coord (ft)
BF-1,2 - FLORIDAN AQUIFER WELLS ON C-13BF-1925619669566

Start Test Date:26-FEB-1993 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):64Horizontal K (ft/day):
Hours Pumped:3.8Vertical K (ft/day):
Tested Interval Min. (ft BLS):1494Storativity:
Tested Interval Max. (ft BLS):1540Leakance (1/day):
No. Monitored Wells:1Specific Capacity (gpm/ft):13.42
SourceReferenceCitation Id
SOUTH FLORIDA WMD LUKASIEWICZ, DRAFT WS-15 TECH PUB213
Comments:5 OF 6 PACKER TESTS

View Water Quality Results for the Above Test



Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
BF-1
925619
669566
THEIS RECOVERY
0
7
21053



SitePumped WellX-Coord(ft)Y-Coord (ft)
BF-1,2 - FLORIDAN AQUIFER WELLS ON C-13BF-1925619669566

Start Test Date:31-MAR-1993 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):65Horizontal K (ft/day):
Hours Pumped:3.5Vertical K (ft/day):
Tested Interval Min. (ft BLS):1000Storativity:
Tested Interval Max. (ft BLS):1031Leakance (1/day):
No. Monitored Wells:1Specific Capacity (gpm/ft):18.57
SourceReferenceCitation Id
SOUTH FLORIDA WMD LUKASIEWICZ, WS-15 DRAFT TECH PUB213
Comments:6 OF 6 PACKER TESTS.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
BF-1
925619
669566
THEIS RECOVERY
0
7
21053

Page generated at: 04-OCT-2025 05:01 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?