DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
BF-1,2 - FLORIDAN AQUIFER WELLS ON C-13BF-2925591669599

Start Test Date:17-OCT-1993 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):9044
Discharge Rate (gal/min):1070Horizontal K (ft/day):
Hours Pumped:72Vertical K (ft/day):
Tested Interval Min. (ft BLS):1500Storativity:.00005
Tested Interval Max. (ft BLS):1600Leakance (1/day):.00029
No. Monitored Wells:2Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD LUKASIEWICZ, DRAFT WS-15 TECHNICAL PUBLICATION213
Comments:CROSS WELL TOMOGRAPHY WAS ALSO CONDUCTED BY U OF M (TOKUO YAMAMOTO) AT THIS SITE TO MEASURE PERMEABILITY BETWEEN WELLS. REPORT PREPARED FOR THE DISTRICT AND PUBLISHED SEP 8, 1997. 4 WELLS CONTRUCTED HERE. 3 EAST OF THE S36 CAGE AND 1 WEST. TWO PRODUCTION WELLS CONSTRUCTED, ONE EACH IN UPPER AND MIDDLE FLORIDAN FLOW ZONES. 2 APTS CONDUCTED. LEAKANCE VALUE UNIT IS PER DAY.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
BF-4
925173
669561
HANTUSH (1960)
433
9.5
9044
.00005
.00029

Page generated at: 04-OCT-2025 11:43 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?