DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BF-1,2 - FLORIDAN AQUIFER WELLS ON C-13
BF-3
925366
669471
Start Test Date:
09-JUN-1997 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
16206
Discharge Rate (gal/min):
980
Horizontal K (ft/day):
Hours Pumped:
67
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1000
Storativity:
.00037
Tested Interval Max. (ft BLS):
1200
Leakance (1/day):
.0002
No. Monitored Wells:
3
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
DRAFT PROJECT SUMMARY C-13 SITE WS-15 TECHNICAL PUBLICATION, LUKASIEWICZ ET AL
213
Comments:
TWO ATTEMPTS AT THIS APT, THE FIRST ONE WAS CONDUCTED IN 1993 AND FAILED 12 HOURS AFTER PUMPING BEGAN BECAUSE OF SEDIMENT LOAD UP IN THE WELL. THIS SECOND ONE CONDUCTED 4 YEARS LATER. ALSO AVAILABLE ON THIS SITE IS A CROSSWELL TOMPOGRAPHY EXPERIMENT BY U OF M, TOKUO YAMAMOTO. BF-5 WAS PRODUCTION WELL USED IN THIS APT BUT SHOWN AS BF-4 IN ANALYSIS INFO BECUASE BF-5 STATION DID NOT EXIST. LEAKANCE VALUE UNIT IS IN PER DAY.
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
BF-4
925173
669561
HANTUSH (1960)
365
6.1
15989
.00037
.0002
Page generated at: 04-OCT-2025 06:37 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?