DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
BIG CYPRESS FLORIDAN TEST SITEBICY-PW554523567149

Start Test Date:13-APR-1998 0000Aquifer:INTERMEDIATE AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):68022
Discharge Rate (gal/min):2700Horizontal K (ft/day):
Hours Pumped:4Vertical K (ft/day):
Tested Interval Min. (ft BLS):465Storativity:.000068
Tested Interval Max. (ft BLS):550Leakance (1/day):.002
No. Monitored Wells:2Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD Bennett, Michael W., P.G., February 2004, Hydrogeologic Investigation of the Floridan Aquifer System Big Cypress Preserve Collier County, Florida Technical Publication WS-18.13
Comments:BASED ON THE MOENCH ANALYTICAL MODEL. Obs well = BICY-MZ1 (BICY-TW)



SitePumped WellX-Coord(ft)Y-Coord (ft)
BIG CYPRESS FLORIDAN TEST SITEBICY-PW554523567149

Start Test Date:14-JUL-1998 0000Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:APTTransmissivity (ft2/day):11209
Discharge Rate (gal/min):820Horizontal K (ft/day):
Hours Pumped:50Vertical K (ft/day):
Tested Interval Min. (ft BLS):840Storativity:.000005
Tested Interval Max. (ft BLS):1010Leakance (1/day):.000086
No. Monitored Wells:2Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD Bennett, Michael W., P.G., February 2004, Hydrogeologic Investigation of the Floridan Aquifer System Big Cypress Preserve Collier County, Florida Technical Publication WS-18.13
Comments:LEAKANCE WAS FOUND TO BE EVENLY DISTRIBUTED BETWEEN THE UPPER AND LOWER CONFININING UNITS. T & S VALUES CALCULATED USING THE MOENCH SOLUTION.

Page generated at: 28-SEP-2024 21:27 EDT