DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MERRITT ISLAND INJECTION WELL SYSTEM
BR1217
751165
1486937
Start Test Date:
08-MAR-1984 0001
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
81.7
Discharge Rate (gal/min):
50
Horizontal K (ft/day):
.765
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
950
Storativity:
Tested Interval Max. (ft BLS):
1055
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
GERAGHTY, SEPT 1984, EXPLORATORY WELL CONSTRUCTION AND TESTING RPT FOR INJECTION FEASIBILITY
Comments:
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MERRITT ISLAND INJECTION WELL SYSTEM
BR1217
751165
1486937
Start Test Date:
08-MAR-1984 0002
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
23.7
Discharge Rate (gal/min):
50
Horizontal K (ft/day):
.224
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1507
Storativity:
Tested Interval Max. (ft BLS):
1612
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
GERAGHTY, SEPT 1984, EXPLORATORY WELL CONSTRUCTION AND TESTING RPT FOR INJECTION FEASIBILITY
Comments:
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MERRITT ISLAND INJECTION WELL SYSTEM
BR1217
751165
1486937
Start Test Date:
08-MAR-1984 0003
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
1.56
Discharge Rate (gal/min):
50
Horizontal K (ft/day):
.034
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1615
Storativity:
Tested Interval Max. (ft BLS):
1660
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
GERAGHTY, SEPT 1984, EXPLORATORY WELL CONSTRUCTION AND TESTING RPT FOR INJECTION FEASIBILITY
Comments:
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MERRITT ISLAND INJECTION WELL SYSTEM
BR1217
751165
1486937
Start Test Date:
08-MAR-1984 0004
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
64.2
Discharge Rate (gal/min):
50
Horizontal K (ft/day):
.021
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1685
Storativity:
Tested Interval Max. (ft BLS):
1730
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
GERAGHTY, SEPT 1984, EXPLORATORY WELL CONSTRUCTION AND TESTING RPT FOR INJECTION FEASIBILITY
Comments:
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MERRITT ISLAND INJECTION WELL SYSTEM
BR1217
751165
1486937
Start Test Date:
08-MAR-1984 0005
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
43.4
Discharge Rate (gal/min):
50
Horizontal K (ft/day):
1.42
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1693
Storativity:
Tested Interval Max. (ft BLS):
1798
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
GERAGHTY, SEPT 1984, EXPLORATORY WELL CONSTRUCTION AND TESTING RPT FOR INJECTION FEASIBILITY
Comments:
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MERRITT ISLAND INJECTION WELL SYSTEM
BR1217
751165
1486937
Start Test Date:
08-MAR-1984 0006
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
21.1
Discharge Rate (gal/min):
50
Horizontal K (ft/day):
.397
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1730
Storativity:
Tested Interval Max. (ft BLS):
1775
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
GERAGHTY, SEPT 1984, EXPLORATORY WELL CONSTRUCTION AND TESTING RPT FOR INJECTION FEASIBILITY
Comments:
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MERRITT ISLAND INJECTION WELL SYSTEM
BR1217
751165
1486937
Start Test Date:
08-MAR-1984 0007
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
22.1
Discharge Rate (gal/min):
50
Horizontal K (ft/day):
.207
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1800
Storativity:
Tested Interval Max. (ft BLS):
1905
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
GERAGHTY, SEPT 1984, EXPLORATORY WELL CONSTRUCTION AND TESTING RPT FOR INJECTION FEASIBILITY
Comments:
Page generated at: 04-OCT-2025 05:28 EDT