DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
Bradenton WWTD Injection Well
BRADENTONI
110061
1142638
Start Test Date:
25-DEC-2000 0000
Aquifer:
AVON-PARK PERMEABLE ZONE
Test Type:
STEP-DRAWDOWN
Transmissivity (ft2/day):
280749
Discharge Rate (gal/min):
Horizontal K (ft/day):
Hours Pumped:
12
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1067
Storativity:
Tested Interval Max. (ft BLS):
1659
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , CH2M Hill, 1989.
Comments:
T value was from a step-drawdown test (4 steps increasing from 2,000 to 11,800 gpm); drawdown was corrected for friction and formation losses.:Tested Formation -AP
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
Bradenton WWTD Injection Well
BRADENTONI
110061
1142638
Start Test Date:
25-DEC-2000 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
7.75
Discharge Rate (gal/min):
Horizontal K (ft/day):
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
Storativity:
Tested Interval Max. (ft BLS):
1017
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , CH2M Hill, 1989.
Comments:
Low T is representative of tight zone between the lower Ocala and Upper Avon Park. T is an average value of 4 packer tests at various intervals between 820' and 1,017'. Pumping rate varied from 1.5 to 40 gpm.:Tested Formation -Oc
Page generated at: 04-OCT-2025 03:55 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?