DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BONITA SPRINGS UTILITIES
BS_WRF-MW1
392866
742439
Start Test Date:
13-DEC-0005 0001
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
64.2
Discharge Rate (gal/min):
100
Horizontal K (ft/day):
Hours Pumped:
2
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1110
Storativity:
Tested Interval Max. (ft BLS):
1200
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, OCT. 2004, WATER RECLAMATION FACILITY DEEP INJECTION WELL ENGINEERING REPORT
Comments:
T VALUE IS THEIS RECOVERY METHOD
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BONITA SPRINGS UTILITIES
BS_WRF-MW1
392866
742439
Start Test Date:
21-NOV-2003 0001
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.42
Discharge Rate (gal/min):
2
Horizontal K (ft/day):
.01
Hours Pumped:
3.5
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1450
Storativity:
Tested Interval Max. (ft BLS):
1480
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, OCT. 2004, WATER RECLAMATION FACILITY DEEP INJECTION WELL ENGINEERING REPORT
Comments:
T VALUE IS THEIS RECOVERY METHOD
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BONITA SPRINGS UTILITIES
BS_WRF-MW1
392866
742439
Start Test Date:
25-NOV-2003 0001
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.6
Discharge Rate (gal/min):
1
Horizontal K (ft/day):
.02
Hours Pumped:
2.5
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1520
Storativity:
Tested Interval Max. (ft BLS):
1550
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, OCT. 2004, WATER RECLAMATION FACILITY DEEP INJECTION WELL ENGINEERING REPORT
Comments:
T VALUE IS THEIS RECOVERY METHOD
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BONITA SPRINGS UTILITIES
BS_WRF-MW1
392866
742439
Start Test Date:
26-NOV-2003 0001
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
3.61
Discharge Rate (gal/min):
11
Horizontal K (ft/day):
.12
Hours Pumped:
2
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1680
Storativity:
Tested Interval Max. (ft BLS):
1710
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, OCT. 2004, WATER RECLAMATION FACILITY DEEP INJECTION WELL ENGINEERING REPORT
Comments:
T VALUE IS THEIS RECOVERY METHOD
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BONITA SPRINGS UTILITIES
BS_WRF-MW1
392866
742439
Start Test Date:
03-DEC-2003 0001
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.45
Discharge Rate (gal/min):
.5
Horizontal K (ft/day):
.03
Hours Pumped:
5.2
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1643
Storativity:
Tested Interval Max. (ft BLS):
1658
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, OCT. 2004, WATER RECLAMATION FACILITY DEEP INJECTION WELL ENGINEERING REPORT
Comments:
T VALUE IS THEIS RECOVERY METHOD
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BONITA SPRINGS UTILITIES
BS_WRF-MW1
392866
742439
Start Test Date:
05-DEC-2003 0001
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
1161
Discharge Rate (gal/min):
55
Horizontal K (ft/day):
38.7
Hours Pumped:
1
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1255
Storativity:
Tested Interval Max. (ft BLS):
1285
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, OCT. 2004, WATER RECLAMATION FACILITY DEEP INJECTION WELL ENGINEERING REPORT
Comments:
T VALUE IS THEIS RECOVERY METHOD
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BONITA SPRINGS UTILITIES
BS_WRF-MW1
392866
742439
Start Test Date:
05-DEC-2003 0002
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.45
Discharge Rate (gal/min):
2
Horizontal K (ft/day):
.02
Hours Pumped:
4
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1430
Storativity:
Tested Interval Max. (ft BLS):
1460
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, OCT. 2004, WATER RECLAMATION FACILITY DEEP INJECTION WELL ENGINEERING REPORT
Comments:
T VALUE IS THEIS RECOVERY METHOD
Page generated at: 04-OCT-2025 06:31 EDT