DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BONITA SPRINGS UTILITIES
BS_WRF_IW1
392921
742469
Start Test Date:
23-AUG-2003 0001
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
13.5
Discharge Rate (gal/min):
15
Horizontal K (ft/day):
.27
Hours Pumped:
12
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1920
Storativity:
Tested Interval Max. (ft BLS):
1970
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, OCT. 2004, WATER RECLAMATION FACILITY DEEP INJECTION WELL ENGINEERING REPORT
Comments:
T VALUE IS THEIS RECOVERY METHOD
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BONITA SPRINGS UTILITIES
BS_WRF_IW1
392921
742469
Start Test Date:
28-AUG-2003 0001
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
2.05
Discharge Rate (gal/min):
6
Horizontal K (ft/day):
.07
Hours Pumped:
12
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2290
Storativity:
Tested Interval Max. (ft BLS):
2318
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, OCT. 2004, WATER RECLAMATION FACILITY DEEP INJECTION WELL ENGINEERING REPORT
Comments:
T VALUE IS THEIS RECOVERY METHOD
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BONITA SPRINGS UTILITIES
BS_WRF_IW1
392921
742469
Start Test Date:
30-AUG-2003 0001
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.56
Discharge Rate (gal/min):
1.5
Horizontal K (ft/day):
.02
Hours Pumped:
11.75
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2215
Storativity:
Tested Interval Max. (ft BLS):
2243
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, OCT. 2004, WATER RECLAMATION FACILITY DEEP INJECTION WELL ENGINEERING REPORT
Comments:
T VALUE IS THEIS RECOVERY METHOD
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BONITA SPRINGS UTILITIES
BS_WRF_IW1
392921
742469
Start Test Date:
05-SEP-2003 0001
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.12
Discharge Rate (gal/min):
.75
Horizontal K (ft/day):
0
Hours Pumped:
11
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2100
Storativity:
Tested Interval Max. (ft BLS):
2128
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, OCT. 2004, WATER RECLAMATION FACILITY DEEP INJECTION WELL ENGINEERING REPORT
Comments:
T VALUE IS THEIS RECOVERY METHOD
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BONITA SPRINGS UTILITIES
BS_WRF_IW1
392921
742469
Start Test Date:
10-SEP-2003 0001
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
.21
Discharge Rate (gal/min):
.25
Horizontal K (ft/day):
.01
Hours Pumped:
16
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1870
Storativity:
Tested Interval Max. (ft BLS):
1898
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, OCT. 2004, WATER RECLAMATION FACILITY DEEP INJECTION WELL ENGINEERING REPORT
Comments:
T VALUE IS THEIS RECOVERY METHOD
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BONITA SPRINGS UTILITIES
BS_WRF_IW1
392921
742469
Start Test Date:
12-SEP-2003 0001
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
509
Discharge Rate (gal/min):
250
Horizontal K (ft/day):
.7
Hours Pumped:
3
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2495
Storativity:
Tested Interval Max. (ft BLS):
3220
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, OCT. 2004, WATER RECLAMATION FACILITY DEEP INJECTION WELL ENGINEERING REPORT
Comments:
T VALUE IS THEIS RECOVERY METHOD