DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE RD - ASR
C-1102
429141
623390
Start Test Date:
01-NOV-1990 0001
Aquifer:
INTERMEDIATE CONFINING UNIT
Test Type:
PACKER
Transmissivity (ft2/day):
2400
Discharge Rate (gal/min):
Horizontal K (ft/day):
15
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
300
Storativity:
Tested Interval Max. (ft BLS):
460
Leakance (1/day):
No. Monitored Wells:
0
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:
ALL OF THE STEP-DRAWDOWN TESTS ARE INDICATED TO BE PACKER TESTS; HOWEVER, SOME COULD HAVE BEEN A TEST OF AN OPEN INTERVAL BELOW CASING. FOR STEP TEST, TRANSMISSIVITY WAS DETERMINED AT EACH STEP BY AN UNSPECIFIED METHOD IN WALTON (1970). THEN AN ADJUSTED ESTIMATED VALUE OF TRANSMISSIVITY WAS OBTAINED BY PLOTTING TRANSMISSIVITY AGAINST FLOW RATE FOR EACH STEP.
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE RD - ASR
C-1102
429141
623390
Start Test Date:
01-NOV-1990 0002
Aquifer:
MID-HAWTHORN AQUIFER
Test Type:
PACKER
Transmissivity (ft2/day):
20000
Discharge Rate (gal/min):
Horizontal K (ft/day):
307.69
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
465
Storativity:
Tested Interval Max. (ft BLS):
530
Leakance (1/day):
No. Monitored Wells:
0
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:
ALL OF THE STEP-DRAWDOWN TESTS ARE INDICATED TO BE PACKER TESTS; HOWEVER, SOME COULD HAVE BEEN A TEST OF AN OPEN INTERVAL BELOW CASING. FOR STEP TEST, TRANSMISSIVITY WAS DETERMINED AT EACH STEP BY AN UNSPECIFIED METHOD IN WALTON (1970). THEN AN ADJUSTED ESTIMATED VALUE OF TRANSMISSIVITY WAS OBTAINED BY PLOTTING TRANSMISSIVITY AGAINST FLOW RATE FOR EACH STEP.
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE RD - ASR
C-1102
429141
623390
Start Test Date:
01-NOV-1990 0003
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
15000
Discharge Rate (gal/min):
Horizontal K (ft/day):
187.5
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
680
Storativity:
Tested Interval Max. (ft BLS):
760
Leakance (1/day):
No. Monitored Wells:
0
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:
ALL OF THE STEP-DRAWDOWN TESTS ARE INDICATED TO BE PACKER TESTS; HOWEVER, SOME COULD HAVE BEEN A TEST OF AN OPEN INTERVAL BELOW CASING. FOR STEP TEST, TRANSMISSIVITY WAS DETERMINED AT EACH STEP BY AN UNSPECIFIED METHOD IN WALTON (1970). THEN AN ADJUSTED ESTIMATED VALUE OF TRANSMISSIVITY WAS OBTAINED BY PLOTTING TRANSMISSIVITY AGAINST FLOW RATE FOR EACH STEP.
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE RD - ASR
C-1102
429141
623390
Start Test Date:
01-NOV-1990 0004
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
6700
Discharge Rate (gal/min):
Horizontal K (ft/day):
74.44
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
930
Storativity:
Tested Interval Max. (ft BLS):
1020
Leakance (1/day):
No. Monitored Wells:
0
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:
ALL OF THE STEP-DRAWDOWN TESTS ARE INDICATED TO BE PACKER TESTS; HOWEVER, SOME COULD HAVE BEEN A TEST OF AN OPEN INTERVAL BELOW CASING. FOR STEP TEST, TRANSMISSIVITY WAS DETERMINED AT EACH STEP BY AN UNSPECIFIED METHOD IN WALTON (1970). THEN AN ADJUSTED ESTIMATED VALUE OF TRANSMISSIVITY WAS OBTAINED BY PLOTTING TRANSMISSIVITY AGAINST FLOW RATE FOR EACH STEP.
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE RD - ASR
C-1102
429141
623390
Start Test Date:
01-NOV-1990 0005
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
6300
Discharge Rate (gal/min):
Horizontal K (ft/day):
157.5
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1180
Storativity:
Tested Interval Max. (ft BLS):
1220
Leakance (1/day):
No. Monitored Wells:
0
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:
ALL OF THE STEP-DRAWDOWN TESTS ARE INDICATED TO BE PACKER TESTS; HOWEVER, SOME COULD HAVE BEEN A TEST OF AN OPEN INTERVAL BELOW CASING. FOR STEP TEST, TRANSMISSIVITY WAS DETERMINED AT EACH STEP BY AN UNSPECIFIED METHOD IN WALTON (1970). THEN AN ADJUSTED ESTIMATED VALUE OF TRANSMISSIVITY WAS OBTAINED BY PLOTTING TRANSMISSIVITY AGAINST FLOW RATE FOR EACH STEP.
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
MANATEE RD - ASR
C-1102
429141
623390
Start Test Date:
01-NOV-1990 0006
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
5700
Discharge Rate (gal/min):
Horizontal K (ft/day):
21.84
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1345
Storativity:
Tested Interval Max. (ft BLS):
1606
Leakance (1/day):
No. Monitored Wells:
0
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:
ALL OF THE STEP-DRAWDOWN TESTS ARE INDICATED TO BE PACKER TESTS; HOWEVER, SOME COULD HAVE BEEN A TEST OF AN OPEN INTERVAL BELOW CASING. FOR STEP TEST, TRANSMISSIVITY WAS DETERMINED AT EACH STEP BY AN UNSPECIFIED METHOD IN WALTON (1970). THEN AN ADJUSTED ESTIMATED VALUE OF TRANSMISSIVITY WAS OBTAINED BY PLOTTING TRANSMISSIVITY AGAINST FLOW RATE FOR EACH STEP.
Page generated at: 04-OCT-2025 06:44 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?