DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
IMMOKALEE WATER & SEWER - INJECTION & TEST MONITOR WELLC-1246515772756995

Start Test Date:12-OCT-2001 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):141.7
Discharge Rate (gal/min):85Horizontal K (ft/day):2.83
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1950Storativity:
Tested Interval Max. (ft BLS):2000Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT CH2MHILL, APRIL 2002 CONSTRUCTION REPORT
Comments:T VALUE FROM SPECIFIC CAPACITY



SitePumped WellX-Coord(ft)Y-Coord (ft)
IMMOKALEE WATER & SEWER - INJECTION & TEST MONITOR WELLC-1246515772756995

Start Test Date:13-OCT-2001 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):119.5
Discharge Rate (gal/min):60Horizontal K (ft/day):3.98
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1970Storativity:
Tested Interval Max. (ft BLS):2000Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT CH2MHILL, APRIL 2002 CONSTRUCTION REPORT
Comments:T VALUE FROM SPECIFIC CAPACITY



SitePumped WellX-Coord(ft)Y-Coord (ft)
IMMOKALEE WATER & SEWER - INJECTION & TEST MONITOR WELLC-1246515772756995

Start Test Date:07-NOV-2001 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):6.78
Discharge Rate (gal/min):3.5Horizontal K (ft/day):.07
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2800Storativity:
Tested Interval Max. (ft BLS):2901Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT CH2MHILL, APRIL 2002 CONSTRUCTION REPORT
Comments:T VALUE FROM SPECIFIC CAPACITY



SitePumped WellX-Coord(ft)Y-Coord (ft)
IMMOKALEE WATER & SEWER - INJECTION & TEST MONITOR WELLC-1246515772756995

Start Test Date:08-NOV-2001 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):1.95
Discharge Rate (gal/min):.75Horizontal K (ft/day):.06
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2720Storativity:
Tested Interval Max. (ft BLS):2755Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT CH2MHILL, APRIL 2002 CONSTRUCTION REPORT
Comments:T VALUE FROM SPECIFIC CAPACITY



SitePumped WellX-Coord(ft)Y-Coord (ft)
IMMOKALEE WATER & SEWER - INJECTION & TEST MONITOR WELLC-1246515772756995

Start Test Date:11-NOV-2001 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):3.39
Discharge Rate (gal/min):.75Horizontal K (ft/day):.06
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2400Storativity:
Tested Interval Max. (ft BLS):2461Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT CH2MHILL, APRIL 2002 CONSTRUCTION REPORT
Comments:T VALUE FROM SPECIFIC CAPACITY



SitePumped WellX-Coord(ft)Y-Coord (ft)
IMMOKALEE WATER & SEWER - INJECTION & TEST MONITOR WELLC-1246515772756995

Start Test Date:12-NOV-2001 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:PACKERTransmissivity (ft2/day):108.9
Discharge Rate (gal/min):5Horizontal K (ft/day):2.14
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2200Storativity:
Tested Interval Max. (ft BLS):2251Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT CH2MHILL, APRIL 2002 CONSTRUCTION REPORT
Comments:T VALUE FROM SPECIFIC CAPACITY

Page generated at: 28-SEP-2024 21:36 EDT