DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
CF industries - Lake City Limestone?CFIND_AP3383811181275

Start Test Date:02-JAN-1975 0000Aquifer:AVON-PARK PERMEABLE ZONE
Test Type:APTTransmissivity (ft2/day):267379
Discharge Rate (gal/min):Horizontal K (ft/day):1336
Hours Pumped:144Vertical K (ft/day):
Tested Interval Min. (ft BLS):950Storativity:.001
Tested Interval Max. (ft BLS):1175Leakance (1/day):.0000018
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , Darnes and Moore, 1975.
Comments:Tested only the Avon Park Limestone; monitor wells open to the same interval; barometric and regional fluctuations accounted for; monitored the zone below the Avon Park (Lake City Ls.), the upper artesian and the surficial levels; anisotropic conditions;

Page generated at: 03-JUL-2024 08:58 EDT