DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
CF industries - Lake City Limestone?CFIND_TP3383471181167

Start Test Date:01-JAN-1975 0000Aquifer:INTERMEDIATE AQUIFER SYSTEM
Test Type:STEP-DRAWDOWNTransmissivity (ft2/day):400
Discharge Rate (gal/min):Horizontal K (ft/day):
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):370Storativity:.000063
Tested Interval Max. (ft BLS):433Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
 
Comments:Step draw down test Q=1,200 to 2,400 gpm

Page generated at: 04-OCT-2025 10:07 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?