DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
CF industries - Lake City Limestone?
CFIND_TP
338347
1181167
Start Test Date:
01-JAN-1975 0000
Aquifer:
INTERMEDIATE AQUIFER SYSTEM
Test Type:
STEP-DRAWDOWN
Transmissivity (ft2/day):
400
Discharge Rate (gal/min):
Horizontal K (ft/day):
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
370
Storativity:
.000063
Tested Interval Max. (ft BLS):
433
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
Comments:
Step draw down test Q=1,200 to 2,400 gpm