DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
ENGLEWOOD - ASR
CH-318
243045
936528
Start Test Date:
25-DEC-2002 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
61
Discharge Rate (gal/min):
10
Horizontal K (ft/day):
Hours Pumped:
1.33
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
563
Storativity:
Tested Interval Max. (ft BLS):
583
Leakance (1/day):
No. Monitored Wells:
0
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:
MULTIWELL AQUIFER TEST PLANNED IN THE FUTURE
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
CH-318
243045
936528
THEIS RECOVERY
0
60.2
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
ENGLEWOOD - ASR
CH-318
243045
936528
Start Test Date:
31-MAR-2000 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
OTHER
Transmissivity (ft2/day):
636.9
Discharge Rate (gal/min):
490-1050
Horizontal K (ft/day):
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
507
Storativity:
Tested Interval Max. (ft BLS):
700
Leakance (1/day):
No. Monitored Wells:
0
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:
MULTIWELL AQUIFER TEST PLANNED IN THE FUTURE ANALYSIS METHOD SPECIFIC CAPACITY
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
CH-318
243045
936528
OTHER
0
628.3
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
ENGLEWOOD - ASR
CH-318
243045
936528
Start Test Date:
07-MAR-2000 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
176.2
Discharge Rate (gal/min):
131
Horizontal K (ft/day):
1
Hours Pumped:
4
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
630
Storativity:
Tested Interval Max. (ft BLS):
807
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:
MULTIWELL AQUIFER TEST PLANNED IN THE FUTURE ANALYSIS METHOD SPECIFIC CAPACITY
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
CH-318
243045
936528
OTHER
0
173.8
Page generated at: 04-OCT-2025 08:22 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?