DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
APT site for pumped well at CHULUOTA_1
CHULUOTA_1
618740
1568467
Start Test Date:
25-DEC-2000 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
APT
Transmissivity (ft2/day):
8528
Discharge Rate (gal/min):
514
Horizontal K (ft/day):
Hours Pumped:
72
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
122
Storativity:
.0045
Tested Interval Max. (ft BLS):
218
Leakance (1/day):
.015
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
JAMMEL & ASSOCIATES. 1988. EVALUATION OF PUMPING TEST RESULTS, CHULUOTA WELL SITE, SEMINOLE COUNTY, FLORIDA. PROJECT NO. 86-03082.
Comments:
PARAMETER VALUES ARE AVERAGE FROM HANTUSH & JACOB DRAWDOWN AND RECOVERY AND COMPUTER SIMULATED AUTOMATCH METHOD FOR DRAWDOWN AND RECOVERY.
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
CHULUOTA_2
618539
1568467
HANTUSH-JACOB (1955)
200
9603
.004
.0094
CHULUOTA_2
618539
1568467
OTHER
200
8659
.005
.013