SitePumped WellX-Coord(ft)Y-Coord (ft)
City of Clearwater Upper Zone A (Well 31)CLEAR_31860741327437

Start Test Date:01-JAN-2001 0000Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:APTTransmissivity (ft2/day):9358
Discharge Rate (gal/min):320Horizontal K (ft/day):
Hours Pumped:72Vertical K (ft/day):
Tested Interval Min. (ft BLS):76Storativity:.00019
Tested Interval Max. (ft BLS):152Leakance (1/day):.0027
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
 
Comments:48 hr constant rate following specific capacity testing. Analysis of pumping data via specific capacity. Theis recovery analysis on monitor well. Q=350 to 870 gpm