DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
EXPANSION FOR CITY OF HOLLYWOOD WATER SUPPLY SYSTEMCOHWTP_TW926389611662

Start Test Date:31-AUG-1992 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):24390
Discharge Rate (gal/min):1010Horizontal K (ft/day):
Hours Pumped:120Vertical K (ft/day):
Tested Interval Min. (ft BLS):930Storativity:.0003
Tested Interval Max. (ft BLS):1314Leakance (1/day):.000063
No. Monitored Wells:1Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MISSIMER AND ASSOCIATES, INC. OCTOBER 1992. TECHNICAL MEMORANDUM ON THE CONSTRUCTION AND TESTING OF WELL F-2, CITY OF HOLLYWOOD, FLORIDA.
Comments:



SitePumped WellX-Coord(ft)Y-Coord (ft)
EXPANSION FOR CITY OF HOLLYWOOD WATER SUPPLY SYSTEMCOHWTP_TW926389611662

Start Test Date:05-DEC-2008 0000Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:STEP-DRAWDOWNTransmissivity (ft2/day):28075
Discharge Rate (gal/min):Horizontal K (ft/day):74
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):920Storativity:
Tested Interval Max. (ft BLS):1301Leakance (1/day):
No. Monitored Wells:0Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MALCOLM PIRNIE, NSTALLATION OF PRODUCTION WELLS F10 & F13 AND MAINTENANCE OF WELLS F2, F3 & F5. CITY OF HOLLYWOOD, FL- TECHNICAL MEMORANDUMI. MARCH, 2009.
Comments:TEST CONDUCTED POST ACIDIZATION OF THE WELLBORE TO IMPROVE PERMEABILITY 4 DISCHARGE RATES: 830, 915, 1133 & 1472. T ESTIMATED FROM SPECIFIC CAPACITY

Page generated at: 04-OCT-2025 10:09 EDT