DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
Cone Ranch Wellfield (TP-2)
CONERW_2
306654
1367348
Start Test Date:
25-DEC-2000 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
24799
Discharge Rate (gal/min):
Horizontal K (ft/day):
45.09
Hours Pumped:
335
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
150
Storativity:
.00054
Tested Interval Max. (ft BLS):
700
Leakance (1/day):
.000032
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , Leggette, Brashears & Graham, 1998
Comments:
APT data corrected for water level fluctuations due to rainfall events and regional trends. Approx. 1.7 inches of rainfall received at the APT site during the test. Parameters represent the harmonic mean of 5 analytical methods.:Tested Formation -S-Oc-AP
Page generated at: 04-OCT-2025 05:28 EDT