DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
Cone Ranch Wellfield (TP-3)CONERW_33023271388113

Start Test Date:25-DEC-2000 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):37005
Discharge Rate (gal/min):Horizontal K (ft/day):67.28
Hours Pumped:335Vertical K (ft/day):
Tested Interval Min. (ft BLS):150Storativity:.00028
Tested Interval Max. (ft BLS):700Leakance (1/day):.000028
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , Leggette, Brashears & Graham, 1998
Comments:APT data corrected for water level fluctuations due to rainfall events and regional trends. Approx. 1.7 inches of rainfall received at the APT site during the test. Parameters represent the harmonic mean of 5 analytical methods.:Tested Formation -S-Oc-AP

Page generated at: 04-APR-2025 15:02 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?