DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
POLK CENTRAL REG. UTILITY SERVICE AREA - BARTOW
CPOLK-TPW1
398323
1315816
Start Test Date:
12-DEC-2016 1844
Aquifer:
MCUII - EVAPORITIC (WSP 1403)
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
5.00
Horizontal K (ft/day):
Hours Pumped:
1.87
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1250
Storativity:
Tested Interval Max. (ft BLS):
2280
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
.5
Source
Reference
Citation Id
CONSULTANT
274
Comments:
Test not adjusted for friction losses; Specific Conductance [uS/cm] = 4600 / TDS [mg/L] = 3700;
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
POLK CENTRAL REG. UTILITY SERVICE AREA - BARTOW
CPOLK-TPW1
398323
1315816
Start Test Date:
13-DEC-2016 0902
Aquifer:
LOWER FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
62.00
Horizontal K (ft/day):
Hours Pumped:
6.02
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2280
Storativity:
Tested Interval Max. (ft BLS):
3120
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
5.3
Source
Reference
Citation Id
CONSULTANT
274
Comments:
Test not adjusted for friction losses; Specific Conductance [uS/cm] = 5900 / TDS [mg/L] = 4700; LF-1, LF-2, LF-3
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
POLK CENTRAL REG. UTILITY SERVICE AREA - BARTOW
CPOLK-TPW1
398323
1315816
Start Test Date:
14-DEC-2016 1130
Aquifer:
SUB-FLORIDAN CONFINING UNIT
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
2.50
Horizontal K (ft/day):
Hours Pumped:
2.97
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2655
Storativity:
Tested Interval Max. (ft BLS):
3120
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
.05
Source
Reference
Citation Id
CONSULTANT
274
Comments:
Test not adjusted for friction losses; Specific Conductance [uS/cm] = 5900 / TDS [mg/L] = 4800;
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
POLK CENTRAL REG. UTILITY SERVICE AREA - BARTOW
CPOLK-TPW1
398323
1315816
Start Test Date:
15-DEC-2016 0736
Aquifer:
LOWER FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
64.40
Horizontal K (ft/day):
Hours Pumped:
5.98
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1250
Storativity:
Tested Interval Max. (ft BLS):
2655
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
8.1
Source
Reference
Citation Id
CONSULTANT
274
Comments:
Test not adjusted for friction losses; Specific Conductance [uS/cm] = 4400 / TDS [mg/L] = 3800; LF-1, LF-2, LF-3
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
POLK CENTRAL REG. UTILITY SERVICE AREA - BARTOW
CPOLK-TPW1
398323
1315816
Start Test Date:
20-DEC-2016 1400
Aquifer:
LOWER FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
48.60
Horizontal K (ft/day):
Hours Pumped:
3.95
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2474
Storativity:
Tested Interval Max. (ft BLS):
3120
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
2.1
Source
Reference
Citation Id
CONSULTANT
274
Comments:
Test not adjusted for friction losses; Specific Conductance [uS/cm] = 10000 / TDS [mg/L] = 7400; LF-3 (2,550-2,580 ft)
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
POLK CENTRAL REG. UTILITY SERVICE AREA - BARTOW
CPOLK-TPW1
398323
1315816
Start Test Date:
21-DEC-2016 0831
Aquifer:
LOWER FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
66.40
Horizontal K (ft/day):
Hours Pumped:
7.62
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1250
Storativity:
Tested Interval Max. (ft BLS):
2474
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
6.5
Source
Reference
Citation Id
CONSULTANT
274
Comments:
Test not adjusted for friction losses; Specific Conductance [uS/cm] = 5200 / TDS [mg/L] = 4500; LF-1 and LF-2
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
POLK CENTRAL REG. UTILITY SERVICE AREA - BARTOW
CPOLK-TPW1
398323
1315816
Start Test Date:
22-DEC-2016 0931
Aquifer:
LOWER FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
58.00
Horizontal K (ft/day):
Hours Pumped:
5.02
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1250
Storativity:
Tested Interval Max. (ft BLS):
2382
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
2.3
Source
Reference
Citation Id
CONSULTANT
274
Comments:
Test not adjusted for friction losses; Specific Conductance [uS/cm] = 5500 / TDS [mg/L] = 4500; LF-1 (2,340-2,380 ft)
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
POLK CENTRAL REG. UTILITY SERVICE AREA - BARTOW
CPOLK-TPW1
398323
1315816
Start Test Date:
27-DEC-2016 0729
Aquifer:
LOWER FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
63.00
Horizontal K (ft/day):
Hours Pumped:
5.92
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2382
Storativity:
Tested Interval Max. (ft BLS):
3120
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
4.8
Source
Reference
Citation Id
CONSULTANT
274
Comments:
Test not adjusted for friction losses; Specific Conductance [uS/cm] = 8700 / TDS [mg/L] = 6300; LF-2 and LF-3
Page generated at: 04-OCT-2025 06:38 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?