DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
Cross Bar Ranch Well A
CROSSBARA
191720
1484986
Start Test Date:
25-DEC-2000 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
50267
Discharge Rate (gal/min):
Horizontal K (ft/day):
96.67
Hours Pumped:
89
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
72
Storativity:
.0003
Tested Interval Max. (ft BLS):
625
Leakance (1/day):
.000064
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , Leggette, Brashears, and Graham, 1978.
Comments:
2 tests were made for confirmation; rain hindered the test and the data were not corrected for regional fluctuations:Tested Formation -Tp-S-Oc-AP
Page generated at: 29-SEP-2024 00:24 EDT