DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
LEC MIAMI-DADE EXPLORATORY WELL SITE AT L-30N CANAL
DF-1
828435
575985
Start Test Date:
12-DEC-1996 0000
Aquifer:
AVON-PARK PERMEABLE ZONE
Test Type:
APT
Transmissivity (ft2/day):
4298
Discharge Rate (gal/min):
100
Horizontal K (ft/day):
Hours Pumped:
38
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1700
Storativity:
.00009
Tested Interval Max. (ft BLS):
1800
Leakance (1/day):
.000051
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
LUKASIEWICZ, J. 2003. FLORIDAN AQUIFER SYSTEM TEST WELL PROGRAM, L-30N CANAL, MIAMI-DADE, FL. SFWMD TP WS-17.
212
Comments:
DISCHARGE RATE RANGED FROM 76 - 110 GPM BUT HELD RELATIVELY CONSTANT AT 100 GPM. SPECIFIC CAPACITY = 32 GPM/FT
View Water Quality Results for the Above Test
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
KRM-TZMW
830843
573318
HANTUSH-JACOB (1955)
203
3.2
4374
.00009
.000051
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
LEC MIAMI-DADE EXPLORATORY WELL SITE AT L-30N CANAL
DF-1
828435
575985
Start Test Date:
13-OCT-1993 0000
Aquifer:
LOWER FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
64
Horizontal K (ft/day):
Hours Pumped:
5
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
2565
Storativity:
Tested Interval Max. (ft BLS):
2640
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
LUKASIEWICZ, J. 2003. FLORIDAN AQUIFER SYSTEM TEST WELL PROGRAM, L-30N CANAL, MIAMI-DADE, FL. SFWMD TP WS-17.
212
Comments:
SPECIFIC CAPACITY = 30.5 GPM/FT
View Water Quality Results for the Above Test
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
LEC MIAMI-DADE EXPLORATORY WELL SITE AT L-30N CANAL
DF-1
828435
575985
Start Test Date:
16-OCT-1993 0000
Aquifer:
AVON-PARK PERMEABLE ZONE
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
102
Horizontal K (ft/day):
Hours Pumped:
4.45
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1720
Storativity:
Tested Interval Max. (ft BLS):
1768
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
LUKASIEWICZ, J. 2003. FLORIDAN AQUIFER SYSTEM TEST WELL PROGRAM, L-30N CANAL, MIAMI-DADE, FL. SFWMD TP WS-17.
212
Comments:
SPECIFIC CAPACITY = 4.5 GPM/FT