DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
LEC MIAMI-DADE EXPLORATORY WELL SITE AT L-30N CANAL
DF-2
830647
573068
Start Test Date:
05-DEC-1996 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
7220
Discharge Rate (gal/min):
435
Horizontal K (ft/day):
Hours Pumped:
67
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1140
Storativity:
.0013
Tested Interval Max. (ft BLS):
1230
Leakance (1/day):
.0018
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
LUKASIEWICZ, J. 2003. FLORIDAN AQUIFER SYSTEM TEST WELL PROGRAM, L-30N CANAL, MIAMI-DADE, FL. SFWMD TP WS-17.
212
Comments:
DISCHARGE RATE RANGED FROM 420 - 510 GPM BUT HELD RELATIVELY CONSTANT AT 435 GPM ANLAYSIS METHOD IS MOENCH, 1985. SPECIFIC CAPACITY = 140 GPM/FT
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
KRM-TZMW
830843
573318
OTHER
508
7123
.0013
.0018
Page generated at: 04-OCT-2025 11:50 EDT