DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
EASTERN HILLSBOROEHILL_ASR910874727880

Start Test Date:29-APR-2002 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):19241
Discharge Rate (gal/min):3400Horizontal K (ft/day):
Hours Pumped:24Vertical K (ft/day):
Tested Interval Min. (ft BLS):1010Storativity:
Tested Interval Max. (ft BLS):1225Leakance (1/day):
No. Monitored Wells:1Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT PALM BEACH COUNTY WATER UTILITIES DEPARTMENT. SECTION 2 - CONSTRUCTION AND TESTING PROGRAM.
Comments:INCREMENTAL PUMPING RATES OF APPROXIMATELY 1800 GPM, 3000 GPM AND 3400GPM WERE UTILIZED FOR THE PUMPING TEST. WATER LEVELS WERE MEASURED IN THE WELL DURING EACH PUMPING RATE FOR APPROX. 1 HOUR THEN THE RATE WAS INCREASED TO THE NEXT PUMPING RATE. THE FINAL RATE WAS CONTINUED FOR THE REMAINDER OF THE 24 HOURS TESTING PERIOD. TRANS VALE DETERMINED USING AQTESOLV (COMPUTER PROG FOR TEST ANALYSIS).

Page generated at: 04-OCT-2025 11:44 EDT