DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
Englewood Wellfield CompositeENGS17C213062976449

Start Test Date:01-JAN-1978 0000Aquifer:SANDSTONE AQUIFER
Test Type:APTTransmissivity (ft2/day):2600
Discharge Rate (gal/min):150Horizontal K (ft/day):
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):40Storativity:.00033
Tested Interval Max. (ft BLS):70Leakance (1/day):.00027
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD CH2M Hill, 1978. p. 9-1,Table 6-3; Hutchinson, 1992. p. 13,20.
Comments:RECOMMENDED VALUES ARE COMPOSITE AQUIFER CHARACTERISTICS FOR THE WELLFIELD, AVG OF 5 SEPARATE TESTS (525 - 3700 FT2/D RANGE) CONDUCTED IN AUGUST AND SEPTEMBER OF 1978.

Page generated at: 01-JUL-2024 08:58 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?