DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
East Sun City Area (Peek Test Site)
ESUN_CITY
183278
1220593
Start Test Date:
25-DEC-2000 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
15374
Discharge Rate (gal/min):
Horizontal K (ft/day):
Hours Pumped:
31
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
65
Storativity:
.0006
Tested Interval Max. (ft BLS):
770
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTHWEST FLORIDA WMD
Data compiled by the SWFMWD, originally from , Peek, 1959; Menke, Meredith and Wetterhall, 1961.
Comments:
Leaky artesian type curve may have yielded different results; no corrections were made for barometric or regional effects; no well construction data; low values indicate partial penetration.:Tested Formation -Tp-S
Page generated at: 28-SEP-2024 19:52 EDT