DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
East Sun City Area (Peek Test Site)ESUN_CITY1832781220593

Start Test Date:25-DEC-2000 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):15374
Discharge Rate (gal/min):Horizontal K (ft/day):
Hours Pumped:31Vertical K (ft/day):
Tested Interval Min. (ft BLS):65Storativity:.0006
Tested Interval Max. (ft BLS):770Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , Peek, 1959; Menke, Meredith and Wetterhall, 1961.
Comments:Leaky artesian type curve may have yielded different results; no corrections were made for barometric or regional effects; no well construction data; low values indicate partial penetration.:Tested Formation -Tp-S

Page generated at: 28-SEP-2024 19:52 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?