DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
EVERGLADES CLUBEVERCLUB970852860148

Start Test Date:25-DEC-2001 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:STEP-DRAWDOWNTransmissivity (ft2/day):2811
Discharge Rate (gal/min):275Horizontal K (ft/day):
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1052Storativity:
Tested Interval Max. (ft BLS):1267Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT GERHARDT M. WITT & ASSOCIATES. 2002. THE EVERGLADES CLUB FLORIDAN AQUIFER PRODUCTION WELL, WELL COMPLETION REPORT.
Comments:SPECIFIC CAPACITY = 56.82 GPM/FT AT 60 MIN. TRANSMISSIVITY ESTIMATED FROM COOPER-JACOB ANALYSIS METHOD DERIVED FROM SPECIFIC CAPACITY.



SitePumped WellX-Coord(ft)Y-Coord (ft)
EVERGLADES CLUBEVERCLUB970852860148

Start Test Date:25-DEC-2001 0100Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:STEP-DRAWDOWNTransmissivity (ft2/day):1878
Discharge Rate (gal/min):525Horizontal K (ft/day):
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1052Storativity:
Tested Interval Max. (ft BLS):1267Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT GERHARDT M. WITT & ASSOCIATES. 2002. THE EVERGLADES CLUB FLORIDAN AQUIFER PRODUCTION WELL, WELL COMPLETION REPORT.
Comments:SPECIFIC CAPACITY = 42.20 GPM/FT FOR 60 MIN. TRANSMISSIVITY ESTIMATED FROM COOPER-JACOB ANALYSIS METHOD DERIVED FROM SPECIFIC CAPACITY.



SitePumped WellX-Coord(ft)Y-Coord (ft)
EVERGLADES CLUBEVERCLUB970852860148

Start Test Date:25-DEC-2001 0200Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:STEP-DRAWDOWNTransmissivity (ft2/day):2292
Discharge Rate (gal/min):833.5Horizontal K (ft/day):
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1052Storativity:
Tested Interval Max. (ft BLS):1267Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT GERHARDT M. WITT & ASSOCIATES. 2002. THE EVERGLADES CLUB FLORIDAN AQUIFER PRODUCTION WELL, WELL COMPLETION REPORT.
Comments:SPECIFIC CAPACITY = 42.02 GPM/FT FOR 60 MIN. TRANSMISSIVITY ESTIMATED FROM COOPER-JACOB ANALYSIS METHOD DERIVED FROM SPECIFIC CAPACITY.

Page generated at: 04-OCT-2025 05:01 EDT