SitePumped WellX-Coord(ft)Y-Coord (ft)
Farmland Industries Well FIF-1FIF-13640281143995

Start Test Date:25-DEC-2000 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):70588
Discharge Rate (gal/min):Horizontal K (ft/day):70
Hours Pumped:247Vertical K (ft/day):
Tested Interval Min. (ft BLS):472Storativity:.0025
Tested Interval Max. (ft BLS):1400Leakance (1/day):.000041
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , LaMoreaux and Associaties, 1979. Weber, 1982(b).
Comments:T value is an average estimate from the analysis of 3 OB wells' drawdown data and 1 OB well's recovery data; regional fluctuations accounted for; also monitored the upper artesian and surficial zones; barometric and rainfall trends unknown; analytical met