SitePumped WellX-Coord(ft)Y-Coord (ft)
FKAA - STOCK ISLANDFKAA-SIASR41225182410

Start Test Date:17-FEB-1993 0830Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):256.4
Discharge Rate (gal/min):198.6Horizontal K (ft/day):
Hours Pumped:24Vertical K (ft/day):
Tested Interval Min. (ft BLS):680Storativity:
Tested Interval Max. (ft BLS):716Leakance (1/day):
No. Monitored Wells:1Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT CH2MHILL, FEBRUARY 1993, LETTER REPORT ASR TEST PROGRAM AT STOCK ISLAND, FLORIDA
Comments:T VALUE IS AVERAGE OF METHODS USED, SEE ANALYSIS

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
FKAA-SIASR
412251
82410
COOPER-JACOB APPROXIMATION
0
55
282.4
FKAA-SIASR
412251
82410
THEIS RECOVERY
0
55
155.6



SitePumped WellX-Coord(ft)Y-Coord (ft)
FKAA - STOCK ISLANDFKAA-SIASR41225182410

Start Test Date:01-NOV-1991 0000Aquifer:
Test Type:SPECIFIC CAPACITYTransmissivity (ft2/day):867.2
Discharge Rate (gal/min):170Horizontal K (ft/day):
Hours Pumped:4Vertical K (ft/day):
Tested Interval Min. (ft BLS):680Storativity:
Tested Interval Max. (ft BLS):715Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT CH2MHILL, MARCH 1992, FLORIDA KEYS ASR TEST PROGRAM AT STOCK ISLAND
Comments:ESTIMATES OF TRANSMISSIVITY WERE MADE FROM A METHOD PRESENTED BY DRISCOLL (1986) RELATING SPECIFIC CAPACITY AND AQUIFER CONDITIONS ACCORDING TO THE EQUATION: T = 2000 Q/S



SitePumped WellX-Coord(ft)Y-Coord (ft)
FKAA - STOCK ISLANDFKAA-SIASR41225182410

Start Test Date:05-NOV-1991 0001Aquifer:
Test Type:SPECIFIC CAPACITYTransmissivity (ft2/day):2466
Discharge Rate (gal/min):700Horizontal K (ft/day):
Hours Pumped:4Vertical K (ft/day):
Tested Interval Min. (ft BLS):680Storativity:
Tested Interval Max. (ft BLS):750Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT CH2MHILL, MARCH 1992, FLORIDA KEYS ASR TEST PROGRAM AT STOCK ISLAND
Comments:ESTIMATES OF TRANSMISSIVITY WERE MADE FROM A METHOD PRESENTED BY DRISCOLL (1986) RELATING SPECIFIC CAPACITY AND AQUIFER CONDITIONS ACCORDING TO THE EQUATION: T = 2000 Q/S



SitePumped WellX-Coord(ft)Y-Coord (ft)
FKAA - STOCK ISLANDFKAA-SIASR41225182410

Start Test Date:05-NOV-1991 0002Aquifer:
Test Type:SPECIFIC CAPACITYTransmissivity (ft2/day):2710
Discharge Rate (gal/min):450Horizontal K (ft/day):
Hours Pumped:4Vertical K (ft/day):
Tested Interval Min. (ft BLS):680Storativity:
Tested Interval Max. (ft BLS):750Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT CH2MHILL, MARCH 1992, FLORIDA KEYS ASR TEST PROGRAM AT STOCK ISLAND
Comments:ESTIMATES OF TRANSMISSIVITY WERE MADE FROM A METHOD PRESENTED BY DRISCOLL (1986) RELATING SPECIFIC CAPACITY AND AQUIFER CONDITIONS ACCORDING TO THE EQUATION: T = 2000 Q/S