DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FLORIDA KEYS AQUEDUCT AUTH JR DEAN WTP-FLORIDA CITY
FKAAFCEW1
818319
403674
Start Test Date:
08-OCT-2003 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
APT
Transmissivity (ft2/day):
10790
Discharge Rate (gal/min):
280
Horizontal K (ft/day):
Hours Pumped:
72
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
880
Storativity:
Tested Interval Max. (ft BLS):
1353
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, 2003, FINAL REPORT- CLASS V EXPLORATORY WELL AT FKAA J. ROBERT DEAN WTP
Comments:
SPECIFIC CAPACITY: 15 GPM/FT **WATER WAS BLENDED WITH RAW WATER FROM BISCAYNE AQUIFER WELLFIELD AND APT INITIATED AS STEP TEST TO ACCOMODATE DISCHARGE TO SEWER SYSTEM. INITAL PUMP RATE OF 280 GPM; INCREASED TO 500 GPM AND 750 GPM FOR FIRST 24 HOURS. RATE DECREASED TO 600 GPM FOR REMAINDER OF TEST AS TDS CONCENTRATION ROSE AT 750 GPM
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FLORIDA KEYS AQUEDUCT AUTH JR DEAN WTP-FLORIDA CITY
FKAAFCEW1
818319
403674
Start Test Date:
02-JUL-2003 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
PACKER
Transmissivity (ft2/day):
29
Discharge Rate (gal/min):
25
Horizontal K (ft/day):
.29
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1050
Storativity:
Tested Interval Max. (ft BLS):
1150
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, 2003, FINAL REPORT- CLASS V EXPLORATORY WELL AT FKAA J. ROBERT DEAN WTP
Comments:
PACKER TEST #1 SPECIFIC CAPACITY: 0.3 GPM/FT SALT PLUG IN WELL WAS NOT COMPLETELY PURGED PRIOR TO START OF TEST- THE INITIAL STATIC WATER LEVEL ASSUMED TO BE THE LEVEL TO WHICH THE WATER LEVEL IN THE DRILL STEM RECOVERED AT CONCLUSION OF TEST
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FLORIDA KEYS AQUEDUCT AUTH JR DEAN WTP-FLORIDA CITY
FKAAFCEW1
818319
403674
Start Test Date:
09-JUL-2003 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
PACKER
Transmissivity (ft2/day):
Discharge Rate (gal/min):
85
Horizontal K (ft/day):
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1220
Storativity:
Tested Interval Max. (ft BLS):
1283
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, 2003, FINAL REPORT- CLASS V EXPLORATORY WELL AT FKAA J. ROBERT DEAN WTP
Comments:
PACKER TEST #2 SPECIFIC CAPACITY: 12 GPM/FT PARAMETERS NOT ANALYZED- NO TYPICAL PUMP OR RECOVERY CURVES-WATER LEVEL RESPONDED SO QUICKLY TO THE START AND STOP OF TEST
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FLORIDA KEYS AQUEDUCT AUTH JR DEAN WTP-FLORIDA CITY
FKAAFCEW1
818319
403674
Start Test Date:
10-JUL-2003 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
PACKER
Transmissivity (ft2/day):
2200
Discharge Rate (gal/min):
82
Horizontal K (ft/day):
34.92
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1150
Storativity:
Tested Interval Max. (ft BLS):
1213
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, 2003, FINAL REPORT- CLASS V EXPLORATORY WELL AT FKAA J. ROBERT DEAN WTP
Comments:
PACKER TEST #3 SPECIFIC CAPACITY: 3 GPM/FT
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FLORIDA KEYS AQUEDUCT AUTH JR DEAN WTP-FLORIDA CITY
FKAAFCEW1
818319
403674
Start Test Date:
22-JUL-2003 0000
Aquifer:
UPPER FLORIDAN AQUIFER (UFA)
Test Type:
PACKER
Transmissivity (ft2/day):
492
Discharge Rate (gal/min):
60
Horizontal K (ft/day):
3.08
Hours Pumped:
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
880
Storativity:
Tested Interval Max. (ft BLS):
1040
Leakance (1/day):
No. Monitored Wells:
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
CONSULTANT
CH2M HILL, 2003, FINAL REPORT- CLASS V EXPLORATORY WELL AT FKAA J. ROBERT DEAN WTP
Comments:
PACKER TEST #4 SPECIFIC CAPACITY: 2 GPM/FT
Page generated at: 04-OCT-2025 06:39 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?