DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
FPL WEST COUNTY ENERGY CENTER (PALM BEACH COUNTY)FPL-DZMW1860302856504

Start Test Date:09-APR-2008 0455Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):15068
Discharge Rate (gal/min):100Horizontal K (ft/day):456.6
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2062Storativity:
Tested Interval Max. (ft BLS):2095Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MCNABB, 12-2008 CONSTRUCTION & TESTING OF DUAL-ZONE MONITOR WELL DZMW-1
Comments:T VALUE CALCULATED FROM SPECIFIC CAPACITY



SitePumped WellX-Coord(ft)Y-Coord (ft)
FPL WEST COUNTY ENERGY CENTER (PALM BEACH COUNTY)FPL-DZMW1860302856504

Start Test Date:09-APR-2008 1345Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):8862
Discharge Rate (gal/min):85Horizontal K (ft/day):268.54
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):2132Storativity:
Tested Interval Max. (ft BLS):2165Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MCNABB, 12-2008 CONSTRUCTION & TESTING OF DUAL-ZONE MONITOR WELL DZMW-1
Comments:T VALUE CALCULATED FROM SPECIFIC CAPACITY



SitePumped WellX-Coord(ft)Y-Coord (ft)
FPL WEST COUNTY ENERGY CENTER (PALM BEACH COUNTY)FPL-DZMW1860302856504

Start Test Date:11-APR-2008 0320Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):11.4
Discharge Rate (gal/min):6.5Horizontal K (ft/day):.34
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1917Storativity:
Tested Interval Max. (ft BLS):1950Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MCNABB, 12-2008 CONSTRUCTION & TESTING OF DUAL-ZONE MONITOR WELL DZMW-1
Comments:T VALUE CALCULATED FROM SPECIFIC CAPACITY



SitePumped WellX-Coord(ft)Y-Coord (ft)
FPL WEST COUNTY ENERGY CENTER (PALM BEACH COUNTY)FPL-DZMW1860302856504

Start Test Date:11-APR-2008 1850Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):3117
Discharge Rate (gal/min):113Horizontal K (ft/day):94.44
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1892Storativity:
Tested Interval Max. (ft BLS):1925Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT MCNABB, 12-2008 CONSTRUCTION & TESTING OF DUAL-ZONE MONITOR WELL DZMW-1
Comments:T VALUE CALCULATED FROM SPECIFIC CAPACITY

Page generated at: 04-OCT-2025 10:27 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?