DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
FT. PIERCE INTERCHANGEFTPIER_PW8507261117891

Start Test Date:23-AUG-1979 0000Aquifer:SURFICIAL AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):1600
Discharge Rate (gal/min):163Horizontal K (ft/day):
Hours Pumped:22.7Vertical K (ft/day):
Tested Interval Min. (ft BLS):70Storativity:
Tested Interval Max. (ft BLS):110Leakance (1/day):
No. Monitored Wells:3Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD SFWMD TECH PUB 96-02 (WRE #337)333
Comments:T VALUES COMPUTED FROM 3 OBSERVATION WELLS NEARLY IDENTICA, . T BASED ON HANTUSH-JACOB

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
100S
850626
1117891
THEIS
100
1970
200W
850726
1117691
THEIS
200
1799
FTPI_OBSD1
850725
1117892
THEIS
60
1784

Page generated at: 28-SEP-2024 19:39 EDT