DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
BROWARD COUNTY WWTP2A: ASR-1G-2889948844713348

Start Test Date:26-NOV-1996 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):5041
Discharge Rate (gal/min):1000Horizontal K (ft/day):
Hours Pumped:24Vertical K (ft/day):
Tested Interval Min. (ft BLS):995Storativity:.000053
Tested Interval Max. (ft BLS):1200Leakance (1/day):
No. Monitored Wells:1Specific Capacity (gpm/ft):
SourceReferenceCitation Id
US GEOLOGICAL SURVEY Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:WALTON METHOD SHOULD GIVE SAME TRANSMISSIVITY IF NO LEAKANCE AS C-J METHOD (?), CURVE MATCHES LOOK OKAY. RECOMMENDED T VALUE DETERMINED WITH C-J METHOD.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
G-2916
948411
713354
COOPER-JACOB APPROXIMATION
4973
.000053
G-2916
948411
713354
WALTON
3864
.00011
G-2889
948844
713348
THEIS RECOVERY
0
5882

Page generated at: 28-SEP-2024 19:49 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?