DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
BROWARD COUNTY WWTP2A: ASR-1
G-2889
948844
713348
Start Test Date:
26-NOV-1996 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
APT
Transmissivity (ft2/day):
5041
Discharge Rate (gal/min):
1000
Horizontal K (ft/day):
Hours Pumped:
24
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
995
Storativity:
.000053
Tested Interval Max. (ft BLS):
1200
Leakance (1/day):
No. Monitored Wells:
1
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:
WALTON METHOD SHOULD GIVE SAME TRANSMISSIVITY IF NO LEAKANCE AS C-J METHOD (?), CURVE MATCHES LOOK OKAY. RECOMMENDED T VALUE DETERMINED WITH C-J METHOD.
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
G-2916
948411
713354
COOPER-JACOB APPROXIMATION
4973
.000053
G-2916
948411
713354
WALTON
3864
.00011
G-2889
948844
713348
THEIS RECOVERY
0
5882
Page generated at: 28-SEP-2024 19:49 EDT