DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FIVEASH WTP - ASR
G-2918
933651
670334
Start Test Date:
12-JAN-1998 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
636.86
Discharge Rate (gal/min):
160
Horizontal K (ft/day):
Hours Pumped:
4
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
998
Storativity:
Tested Interval Max. (ft BLS):
1028
Leakance (1/day):
No. Monitored Wells:
0
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
USGS WRI 02-4036
Comments:
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
G-2918
933651
670334
THEIS RECOVERY
628.34
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FIVEASH WTP - ASR
G-2918
933651
670334
Start Test Date:
13-JAN-1998 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
1084
Discharge Rate (gal/min):
160
Horizontal K (ft/day):
24.64
Hours Pumped:
4
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
998
Storativity:
Tested Interval Max. (ft BLS):
1042
Leakance (1/day):
No. Monitored Wells:
0
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
G-2918
933651
670334
THEIS RECOVERY
1070
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
FIVEASH WTP - ASR
G-2918
933651
670334
Start Test Date:
15-JAN-1998 0000
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
PACKER
Transmissivity (ft2/day):
3117
Discharge Rate (gal/min):
600
Horizontal K (ft/day):
26.64
Hours Pumped:
.06
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
1058
Storativity:
Tested Interval Max. (ft BLS):
1175
Leakance (1/day):
No. Monitored Wells:
0
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:
THIRD PACKER TEST SHOWED APPARENT FAILURE AFTER ABOUT 10 MINUTES, WHICH MAY HAVE AFFECTED DATA. FMW-1 APPARENTLY NOT USED IN 24-HOUR TEST OF ASR-1.
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
G-2918
933651
670334
COOPER-JACOB APPROXIMATION
3075
Page generated at: 04-OCT-2025 13:57 EDT