DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
WEST WELL FIELD - ASR
G-3706
830190
496430
Start Test Date:
09-DEC-1997 0001
Aquifer:
FLORIDAN AQUIFER SYSTEM
Test Type:
STEP-DRAWDOWN
Transmissivity (ft2/day):
15400
Discharge Rate (gal/min):
3500
Horizontal K (ft/day):
Hours Pumped:
72
Vertical K (ft/day):
Tested Interval Min. (ft BLS):
850
Storativity:
.00042
Tested Interval Max. (ft BLS):
1302
Leakance (1/day):
.00082
No. Monitored Wells:
0
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
US GEOLOGICAL SURVEY
Reese, 2002. Inventory and Review of Aquifer Storage & Recovery in Southern Florida. USGS WRI 02-4036
Comments:
ALL THREE AQUIFER STORAGE AND RECOVERY WELLS WERE HEAVILY ACIDIZED PRIOR TO ALL TESTS. LATE TIME DRAWDOWN DATA PROBLEMATIC BECAUSE OF PUMP GOING DOWN SEVERAL TIMES. **RECOMMENDED PARAMETER AVERAGE OF WALTON METHOD FOR BOTH OBSERVATION WELLS.
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
G-3706
830190
496430
COOPER-JACOB APPROXIMATION
0
10300
G-3707
830100
496700
COOPER-JACOB APPROXIMATION
975
18200
.00029
G-3707
830100
496700
WALTON
975
15400
.00039
.0016
G-3708
830160
497420
COOPER-JACOB APPROXIMATION
1355
19700
.00033
G-3708
830160
497420
WALTON
1955
15400
.00044
.000039
Page generated at: 04-OCT-2025 05:26 EDT
DBHYDRO Menu
|
DBHYDRO Home
|
SFWMD Home
|
User's Guide
|
What's New
|
FAQ
|
Comments?