DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
COLLIER ENTERPRISES: GOPHER RIDGEGOPHR-PW1522091763206

Start Test Date:12-JUL-1986 0000Aquifer:SANDSTONE AQUIFER
Test Type:APTTransmissivity (ft2/day):17075
Discharge Rate (gal/min):400Horizontal K (ft/day):186
Hours Pumped:23Vertical K (ft/day):
Tested Interval Min. (ft BLS):40Storativity:.00035
Tested Interval Max. (ft BLS):150Leakance (1/day):.004
No. Monitored Wells:2Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT SFWMD TECHNICAL PUBLICATION 88-12149
Comments:Two scren intervals: 40' to 80' bls and 100' to 150' bls. The WT and LT aquifers were screened.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
MW1
750105
1050184
HANTUSH (1960)
75
4.73
4244
MW2
745115
1046335
HANTUSH (1960)
275
2.59
13810

Page generated at: 04-OCT-2025 10:11 EDT