DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
Grace-HookersGRACEHOOK3489951255365

Start Test Date:25-DEC-2000 0000Aquifer:FLORIDAN AQUIFER SYSTEM
Test Type:APTTransmissivity (ft2/day):116310
Discharge Rate (gal/min):Horizontal K (ft/day):211.47
Hours Pumped:100Vertical K (ft/day):
Tested Interval Min. (ft BLS):359Storativity:.00044
Tested Interval Max. (ft BLS):855Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTHWEST FLORIDA WMD Data compiled by the SWFMWD, originally from , LaMoreaux and Associates, 1975. Silberstein, 1985.
Comments:Leakance result is questionable; well pumped for 24 hours, one day before test began; zones above were monitored.:Tested Formation -S-Oc-AP

Page generated at: 04-OCT-2025 10:12 EDT