DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
TURNER CORP.- NORTH SITEH-M-120474687819814

Start Test Date:12-APR-1985 0000Aquifer:SANDSTONE-CARBONATE ZONE
Test Type:APTTransmissivity (ft2/day):2674
Discharge Rate (gal/min):367Horizontal K (ft/day):42
Hours Pumped:72Vertical K (ft/day):.012
Tested Interval Min. (ft BLS):162Storativity:.00001
Tested Interval Max. (ft BLS):250Leakance (1/day):.00013
No. Monitored Wells:3Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD T.P. 88-12149
Comments:SEE CPI FOR SHALLOW ZONE.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
H-M-121
472128
818249
HANTUSH-JACOB (1955)
51
15.71
2353
.00015
.0015
H-M-122
472128
818249
HANTUSH-JACOB (1955)
101
13.08
2607
.0001
.00041
H-M-123
472128
818249
HANTUSH-JACOB (1955)
390
7.59
3583
.000065
.00024

Page generated at: 04-OCT-2025 05:11 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?