DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
USSC SO. DIV. RANCH IH-M-235667146761305

Start Test Date:27-FEB-1986 0000Aquifer:LOWER TAMIAMI AQUIFER
Test Type:APTTransmissivity (ft2/day):13369
Discharge Rate (gal/min):754Horizontal K (ft/day):223
Hours Pumped:72Vertical K (ft/day):.0084
Tested Interval Min. (ft BLS):65Storativity:.0003
Tested Interval Max. (ft BLS):125Leakance (1/day):.0004
No. Monitored Wells:4Specific Capacity (gpm/ft):
SourceReferenceCitation Id
SOUTH FLORIDA WMD T.P. 88-12149
Comments:Wells possibly partially penetrating.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
H-M-231
662782
763727
HANTUSH-JACOB (1955)
197
5.89
14037
.00037
.00015
H-M-236
662782
763727
HANTUSH-JACOB (1955)
497
4.46
12834
.00039
.00033
H-M-237
662782
763727
HANTUSH-JACOB (1955)
997
2.98
14037
.0005
.00015
H-M-241
662782
763727
HANTUSH-JACOB (1955)
1278
2.39
16444
.0006
.00015

Page generated at: 04-OCT-2025 11:48 EDT