DBHYDRO
reports
Hydraulic Details
Site
Pumped Well
X-Coord(ft)
Y-Coord (ft)
USSC ROGERS RANCH
H-M-310
620447
766036
Start Test Date:
10-FEB-1987 0000
Aquifer:
LOWER TAMIAMI AQUIFER
Test Type:
APT
Transmissivity (ft2/day):
58824
Discharge Rate (gal/min):
882
Horizontal K (ft/day):
654
Hours Pumped:
70
Vertical K (ft/day):
.2
Tested Interval Min. (ft BLS):
65
Storativity:
.00009
Tested Interval Max. (ft BLS):
105
Leakance (1/day):
.0067
No. Monitored Wells:
4
Specific Capacity (gpm/ft):
Source
Reference
Citation Id
SOUTH FLORIDA WMD
T.P. 88-12
149
Comments:
Off-site pumpage appears to effect late time data, only first 3 hrs of data are good
Well Name
X Coord(ft)
Y Coord(ft)
Analysis Method
DistancefromProductionWell(ft)
Max.Drawdown(ft)
Transmissivity(ft**2/day)
Storativity
Leakance
H-M-311
610148
761228
HANTUSH-JACOB (1955)
200
1.58
81551
.00006
.0019
H-M-312
610148
761228
HANTUSH-JACOB (1955)
600
.99
77540
.00015
.0055
H-M-319
610148
761228
HANTUSH-JACOB (1955)
830
.79
64840
.00016
.008
H-M-320
610148
761228
HANTUSH-JACOB (1955)
2200
.38
104278
.00025
.0043
Page generated at: 04-OCT-2025 07:03 EDT