DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
TURNER CORP.- SOUTH SITEH-M-82473136800547

Start Test Date:15-FEB-1983 0000Aquifer:SANDSTONE AQUIFER
Test Type:APTTransmissivity (ft2/day):10027
Discharge Rate (gal/min):475Horizontal K (ft/day):141
Hours Pumped:72Vertical K (ft/day):.000007
Tested Interval Min. (ft BLS):155Storativity:.0001
Tested Interval Max. (ft BLS):240Leakance (1/day):.000001
No. Monitored Wells:2Specific Capacity (gpm/ft):11
SourceReferenceCitation Id
SOUTH FLORIDA WMD T.P. 88-12149
Comments:HM82,HM83 screened 155-175 and open from 189 to 240. HM84 open to both zones.

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
H-M-83
473166
800547
HANTUSH-JACOB (1955)
100
8.71
9626
.00014
.00000096
H-M-84
473166
800500
HANTUSH-JACOB (1955)
316
3.67
18717
.00005
.000011

Page generated at: 04-OCT-2025 10:12 EDT