DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
TOWN OF HIGHLAND BEACH RO WTPHB-TPW1961556755843

Start Test Date:03-AUG-2001 0000Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:APTTransmissivity (ft2/day):13182
Discharge Rate (gal/min):3000Horizontal K (ft/day):.0000094
Hours Pumped:72Vertical K (ft/day):
Tested Interval Min. (ft BLS):1027Storativity:
Tested Interval Max. (ft BLS):1200Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT CH2M HILL, OCTOBER 2001, TECH. MEMORANDUM- CONSTRUCTION & TESTING OF FLORIDAN AQUIFER TEST PRODUCTION WELL TP-1
Comments:VALUES ARE AVERAGE OF PUMPED AND RECOVERY DATA ANALYSIS METHOD: COOPER-JACOB TDS: 6600 MG/L



SitePumped WellX-Coord(ft)Y-Coord (ft)
TOWN OF HIGHLAND BEACH RO WTPHB-TPW1961556755843

Start Test Date:09-AUG-2001 0000Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):330Horizontal K (ft/day):
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1030Storativity:
Tested Interval Max. (ft BLS):1110Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT TECH. MEMORANDUM- CONSTRUCTION & TESTING OF FLORIDAN AQUIFER TEST PRODUCTION WELL TP-1
Comments:PACKER TEST 1 CONDUCTED FOR WQ AND SPECIFIC CAPACITY S.C.= 12.5 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
TOWN OF HIGHLAND BEACH RO WTPHB-TPW1961556755843

Start Test Date:09-AUG-2001 0100Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):575Horizontal K (ft/day):
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1030Storativity:
Tested Interval Max. (ft BLS):1200Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT CH2M HILL, OCTOBER 2001, TECH. MEMORANDUM- CONSTRUCTION & TESTING OF FLORIDAN AQUIFER TEST PRODUCTION WELL TP-1
Comments:PACKER TEST 2 CONDUCTED FOR WQ AND SPECIFIC CAPACITY S.C.= 23.7 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
TOWN OF HIGHLAND BEACH RO WTPHB-TPW1961556755843

Start Test Date:09-AUG-2001 0200Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):670Horizontal K (ft/day):
Hours Pumped:1030Vertical K (ft/day):
Tested Interval Min. (ft BLS):260Storativity:
Tested Interval Max. (ft BLS):Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT CH2M HILL, OCTOBER 2001, TECH. MEMORANDUM- CONSTRUCTION & TESTING OF FLORIDAN AQUIFER TEST PRODUCTION WELL TP-1
Comments:PACKER TEST 3 CONDUCTED FOR WQ AND SPECIFIC CAPACITY S.C.= 29.4 GPM/FT



SitePumped WellX-Coord(ft)Y-Coord (ft)
TOWN OF HIGHLAND BEACH RO WTPHB-TPW1961556755843

Start Test Date:09-AUG-2001 0300Aquifer:UPPER FLORIDAN AQUIFER (UFA)
Test Type:PACKERTransmissivity (ft2/day):
Discharge Rate (gal/min):122Horizontal K (ft/day):
Hours Pumped:Vertical K (ft/day):
Tested Interval Min. (ft BLS):1290Storativity:
Tested Interval Max. (ft BLS):1460Leakance (1/day):
No. Monitored Wells:Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT CH2M HILL, OCTOBER 2001, TECH. MEMORANDUM- CONSTRUCTION & TESTING OF FLORIDAN AQUIFER TEST PRODUCTION WELL TP-1
Comments:PACKER TEST 4 CONDUCTED FOR WQ AND SPECIFIC CAPACITY S.C.= 4.7 GPM/FT

Page generated at: 04-OCT-2025 03:55 EDT

DBHYDRO Menu  |   DBHYDRO Home  |   SFWMD Home  |   User's Guide  |   What's New  |   FAQ |  Comments?