DBHYDRO       reports

Hydraulic Details

SitePumped WellX-Coord(ft)Y-Coord (ft)
HENDRY CORR. INSTHCI12572537716163

Start Test Date:01-JAN-1950 0000Aquifer:LOWER TAMIAMI AQUIFER
Test Type:APTTransmissivity (ft2/day):18970
Discharge Rate (gal/min):100Horizontal K (ft/day):374
Hours Pumped:48Vertical K (ft/day):.14
Tested Interval Min. (ft BLS):97Storativity:.0006
Tested Interval Max. (ft BLS):125Leakance (1/day):
No. Monitored Wells:3Specific Capacity (gpm/ft):
SourceReferenceCitation Id
CONSULTANT LEGGETE, BRASHEARS & GRAHAN, INC
Comments:WELLS POSSIBLY PARTIALLY PENETRATING. POOR DATA, NO GOOD CURVE MATCHES, NO EARLY TIME DATA. USE WITH CAUTION !

Well Name X Coord
(ft)
Y Coord
(ft)
Analysis Method Distance
from
Production
Well
(ft)
Max.
Drawdown
(ft)
Transmissivity
(ft**2/day)
Storativity Leakance
HCI11
572537
716163
JACOB STRAIGHT-LINE (1952)
400
.89
20762
.000002
HCI13
572537
716163
JACOB STRAIGHT-LINE (1952)
400
.59
23850
.000056
HCI14
572537
716163
JACOB STRAIGHT-LINE (1952)
800
.45
19719
.00023

Page generated at: 04-OCT-2025 08:46 EDT